The micro-doughLAB is a small scale (4g) dough mixer and analysis system to analyse the quality and processing features of flour and dough.
The decreased sample size is suited for researchers, wheat breeders, grain handlers, millers and bakers with restricted sample and/or valuable samples.
It may be utilised to screen breeder lines, generate rapid and small scale methods, and to determine the performance, specification, water and mixing requirements of flour. It allows users to save time and prevent unneccesary costs by accurately and hastily identifying the best flour for their needs.
The micro-doughLAB operates from PC with the doughLAB for Windows (DLW) software system. The micro-doughLAB is easy to use, small, reproducible, precise, and cleans up easily.
micro-doughLAB:Small Sample Size: Integrated 4g micro scale bowl. High Speed Mixing: Replicate commercial grade mixers, include ingredients, decrease standard test time to 10 minutes and develop difficult samples. Variable Speed & Temperature: Research dough response to hostile environments. Automated: Built in, automated water dispenser for repeatable, operator independent measurement of water retention. Easy Clean Up: Bowl disassembles quickly for easy cleaning to up sample throughput. User Friendly: Windows software with standard and customizable methods, real time graphs, data analysis, diagnostics and virtual blending function. |
doughLAB for Windows (DLW) Software:Calibration: Followable software calibration procedure. Programmable Instrument Control: “Profile” style method set up with advanced settings and automatic functions for flexibility and easy use. Flexible Data Analysis: Auto functions for commonly calculated parameters and advanced methods for research purposes. Real Time Graph Display: Interactive, and overlay functions for added clarity. Single Page Report: Traceability data, results and the graph all on one page. Traceability: complies with ER/ES (electronic records/electronic signatures) requirements for data security. Virtual blending: View, chart, average, and analyse data to predict the performance of flour blends. |
The micro-doughLAB is a small-scale sigma arm dough mixer which requires 4g of flour and measures water absorption (WA) and dough mixing parameters.
The small sample requirement makes micro-doughLAB well suited for use by wheat breeders and researchers who typically have limited sample available. It can be used to develop rapid and small scale methods that correlate to standard methods.
![]() |
![]() |
![]() |
1) ate micro-doughLAB method in DLW software. Accurately weigh your flour sample using an electronic balance. | 2) Push the bowl guard back away from the bowl. | 3) Dispense the flour sample into the bowl, as shown. |
![]() |
![]() |
![]() |
4) Slide the bowl guard back into place above the bowl and ensure the dispensing arm is positioned over the bowl. Click on “Run” The flour sample will be mixed for the specified zero time. Water will then be added to the sample. | 5) Place the evaporation lid over the bowl. | 6) The resistance of the dough will be graphed on the monitor. |
Wheat flour doughs are nonlinear viscoelastic materials, and as such there is an unusual relationship between the strains displayed during mixing (stretching, shearing, compression and relaxation) and dough resistance. Various factors that are related to processing conditions and flour type will also have a large effect on how the dough reacts. Differences in water and protein content, alterations in the structure of the protein, starch, starch damage, pentosans, gluten strength and the actions of enzymes on the dough components all affect dough behaviour. Due to the complex nature of dough behaviour an empirical instrument test is desirable.
The two vital pieces of information required by millers and bakers are the absorption (amount of water required for a dough to reach a definite consistency) and the mixing profile of the dough (development time, stability and softening) which are indicative of the suitability of the flour for different applications. Other parameters may also be measured.
General |
|
Power Requirements: Computer Requirements: Dimensions (HxDxW): Net Weight: Temperature Range: Speed Range: Speed Accuracy: Torque Range: Torque Accuracy: Dispenser Range: Dispenser Accuracy: |
240/115 VAC, 3A, 50/60 Hz. PC with Windows XP (SP3) or Windows Vista operating system 380x320x550 mm 25 kg Depends on external water bath*. Computer controlled infinitely variable 0 – 200 rpm. +/- 1% at 63 rpm. 0 – 500 mNm. +/-10 mNm at 500 mNm. 0 – 5 ml. +/- 0.01 ml. |
*External water bath needed for temperature control.
Small Sample Size: Integrated 4g micro scale bowl.
Fast
Variable Speed and Temperature
Easy to clean up
doughLAB 230V, 50-60 Hz |
Flexible dough rheomoter with conventional Z-arm mixing action. Built-in automated temperature control and water dispensing. DLW software for instrument operation and data management included in delivery. PC to be provided by customer. Bowl not included, select 300g or 50g bowl below. |
doughLAB bowl 300g incl. Mixing Blades |
doughLAB bowl 50g incl. Mixing Blades |